Description

The Agni Veiga FAP-2001 Intelligent Addressable Active Repeater Panel is designed to provide real-time visibility and control of a connected fire alarm system from strategically located points across a building or large facility. Instead of requiring security personnel, maintenance teams, or emergency responders to return to the main fire alarm control room, the FAP-2001 allows authorized personnel to view live fire alarm information, identify alarm locations, monitor system status, and respond quickly from reception areas, security desks, guard stations, emergency command centers, hospital nursing stations, factory control rooms, and other critical locations. Intelligent Addressable Fire Alarm Repeater Panel: The FAP-2001 operates as an active network repeater panel for compatible Agni Veiga intelligent addressable fire alarm systems. It connects to the Veiga RS-485 communication network through the compatible FAP-3002 network communication card, allowing fire alarm information from the main control panel to be displayed at remote locations. Key capabilities include: • Intelligent Addressable Repeater Operation • 32-Node Network Support • RS-485 Network Communication • Up to 1.2 km Network Segments • Live Fire Alarm Status Monitoring • Remote System Visibility • Remote Alarm Identification • Large Backlit Graphical LCD • Soft-Touch Keypad • 4,000-Event History • Time & Date-Stamped Event Logging • 28V DC Power Supply • IP30 Mild-Steel Enclosure • EN54-2 & EN54-4 Compliance • CE & ERTL/NABL Accreditation 32-Node Fire Alarm Network: The FAP-2001 is designed for larger fire alarm installations requiring multiple interconnected control panels and monitoring points. The network architecture can support up to 32 nodes, allowing compatible fire alarm control panels and repeater panels to communicate across a distributed fire safety network. This makes the system suitable for: • Large Commercial Buildings • Industrial Campuses • Hospitals • University Campuses • Government Complexes • Manufacturing Plants • Multi-Building Facilities • Industrial Townships • Large Institutional Projects Each network segment can extend up to approximately 1.2 km, subject to cable selection, network configuration, installation conditions, and system design. Real-Time Remote Fire Alarm Monitoring: One of the primary advantages of an active repeater panel is the ability to access critical fire alarm information without physically returning to the main control panel. For example, a master fire alarm control panel may be installed inside a secured basement plant room while a repeater panel is positioned at the main security desk or reception area. If a detector activates, personnel at the repeater location can view relevant fire alarm information and identify the associated alarm condition, allowing them to initiate the appropriate emergency response. This distributed monitoring approach can significantly improve situational awareness across large facilities. Large Backlit Graphical LCD Display: The FAP-2001 incorporates a large backlit graphical LCD display designed to provide clear visibility of system information. The display allows personnel to review relevant fire alarm and system status information from remote locations without needing direct access to the primary fire alarm control panel. The graphical interface is complemented by a soft-touch keypad, providing convenient navigation and system interaction. 4,000-Event History Log: The repeater panel maintains a minimum 4,000-event history, providing an organized record of system activity. Events are stored with date and time information, creating an audit trail that can assist facility teams with: • Fire Alarm Investigation • Maintenance Review • System Troubleshooting • Compliance Documentation • Incident Analysis • Post-Incident Reporting • Preventive Maintenance The event history helps transform fire alarm monitoring into a documented and reviewable process. RS-485 Network Communication: The FAP-2001 communicates with the compatible Veiga fire alarm network using RS-485 differential communication technology. The system requires the compatible FAP-3002 network communication card for network connectivity. RS-485 communication is well suited to fire alarm networking because it supports reliable communication over extended cable distances and provides good resistance to electrical noise when correctly installed. Power Supply: The FAP-2001 can receive 28V DC power from the main fire alarm control panel's auxiliary supply or from an appropriate SMPS at the repeater location. This power architecture can simplify installation by allowing the repeater to be supplied as part of the overall fire alarm system infrastructure. The final power arrangement should be designed according to the applicable system documentation, cable requirements, load calculations, and installation standards. Robust Mild-Steel Enclosure: The repeater panel is housed in a 1.2 mm mild-steel enclosure with an IP30 protection rating. The robust enclosure is suitable for installation in controlled indoor environments such as: • Security Control Rooms • Reception Areas • Hospital Nursing Stations • Factory Control Rooms • Government Security Checkpoints • Emergency Command Centres • Building Management Areas Fire Alarm Repeater Panel for Large Facilities: The FAP-2001 is particularly useful when a building or campus contains multiple areas where personnel need immediate access to fire alarm information. Security Desk: Security personnel can monitor fire alarm status without leaving the main security location. Reception Area: Reception and front-desk personnel can access critical alarm information. Hospital Nursing Station: Staff can monitor fire alarm information within designated hospital areas. Factory Control Room: Industrial operators can view fire alarm conditions while continuing to manage facility operations. Government Security Checkpoint: Security teams can access fire alarm status from designated emergency monitoring locations. Emergency Command Centre: Emergency response personnel can use the repeater as an additional monitoring point within the fire safety network. Standards & Certifications: The Agni Veiga FAP-2001 is specified as meeting relevant fire alarm system standards including: EN54-2: Requirements relating to control and indicating equipment. EN54-4: Requirements relating to power supply equipment. IS 2189-2175:1988: Indian fire detection and alarm system requirements as specified for the product. The product also carries CE and ERTL/NABL accreditation as stated by the manufacturer. Project-specific certification, approval, and compliance requirements should always be verified against the latest manufacturer documentation and the requirements of the relevant authority having jurisdiction. Key Product Highlights: Product Model: FAP-2001 Product Type: Intelligent Addressable Active Repeater Panel Network: Agni Veiga RS-485 Network Network Capacity: Up to 32 nodes Network Segment Distance: Up to approximately 1.2 km per segment Required Network Card: FAP-3002 Display: Large Backlit Graphical LCD User Interface: Soft-Touch Keypad Event History: Minimum 4,000 Events Event Recording: Date & Time Stamped Power Supply: 28V DC Enclosure: 1.2 mm Mild Steel Protection Rating: IP30 Standards: EN54-2, EN54-4 and applicable IS requirements Applications: Commercial, Industrial, Institutional, Government and Multi-Building Fire Alarm Networks Ideal B2B Buyers: The Agni Veiga FAP-2001 is suitable for: • Fire Alarm System Integrators • Fire Safety Contractors • Fire Protection Companies • MEP Contractors • Electrical Contractors • Fire Alarm Equipment Distributors • Building Automation Integrators • Industrial Facility Operators • Commercial Property Developers • Hospital Projects • University & Campus Projects • Government Infrastructure Projects • Manufacturing Facilities • Industrial Townships • Large Commercial Complexes Why Choose the Agni Veiga FAP-2001?: The Agni Veiga FAP-2001 Intelligent Addressable Active Repeater Panel provides a practical way to extend fire alarm monitoring beyond the main control room. With 32-node networking, RS-485 communication, up to 1.2 km network segments, a large graphical LCD, 4,000-event history, 28V DC operation, robust mild-steel construction, and integration with the Veiga intelligent addressable fire alarm system, the FAP-2001 is designed for facilities where fast access to fire alarm information is essential. Ideal for global B2B buyers searching for intelligent addressable fire alarm repeater panels, active fire alarm repeater panels, 32-node fire alarm repeaters, RS-485 fire alarm repeater panels, addressable fire alarm monitoring panels, network fire alarm repeaters, Agni Veiga FAP-2001, and multi-building fire alarm network solutions.

Manufacturing & Industrial

Agni Veiga Series Intelligent Addressable Active Repeater Panel – 32 Node Network Fire Alarm Repeater

464.5454545

Listed 8/20/2026

More from Agni Instruments Engineers India Private Limited

Full catalogue →